Specifications

SKU: WIT 50-100K-HU

Weight (KG): 16.7

Dimension: 65 cm (Length) x 55 cm (Width) x 22 cm (Height)

Datasheet WIT 50K-HU WIT 63K-HU WIT 75K-HU WIT 100K-HU
Input Data (PV)        
Max. recommended PV power(for module STC) 109.2kW 124.8kW 156kW 156kW
Start voltage 195V
Max. input voltage 1100V
1 Max. open circuit voltage of PV* 1000V
MPPT nominal voltage/range 550V,180V~800V
Max. input current per MPP tracker 32A
Max. short-circuit current per MPP tracker 40A
No. of PV strings per MPP tracker 2
No. of MPP trackers 7 8 10 10
Output Data (AC)        
AC nominal power 50kW 63kW 75kW 100kW
Max. AC apparent power 55kVA 69.3kVA 82.5kVA 110kVA
Nominal AC voltage/range 380/400/415V,-15%~+10%
Nominal AC grid frequency/range 50/60Hz,45-55Hz/55-65Hz
Max. output current 83.3A 105A 125A 166.7A
Adjustable power factor -1…+1
THDi <3% (@100% load)
AC grid connection type 3P3W+PE/3P4W+PE
Input Data (AC)        
AC nominal power 50kW/100kW 63kW/126kW 75kW/150kW 100kW/200kW
Max. AC apparent power 55kVA/100kVA 69.3kVA/126kVA 82.5kVA/150kVA 110kVA/200kVA
Nominal AC voltage/range 380/400/415V,-15%~+10%
Nominal AC grid frequency/range 50/60Hz,45-55Hz/55-65Hz
Max. input current 83.3A/151.5A 105A/190.9A 125A/227.3A 166.7A/303A
Battery Data (DC)        
Continuous charging and discharging power 56.7kW 71.4kW 85.1kW 113.5kW
Battery voltage range 600-1000V (for 3P3W) / 680-1000V (for 3P4W) (>850V derating)
Recommended battery voltage 768V
Max charging and discharging current 83.3A 105A 125A 167A
BMS communication RS485/CAN
Backup Power (AC)*²        
Rated AC output power 50kW 63kW 75kW 100kW
Max. AC apparent power 60kVA 75.6kVA 90kVA 120kVA
Rated AC output voltage 220V/230V/240V(L-N),380V/400V/415V(L-L)
Nominal AC output frequency 50/60 Hz
Load connection 3P3W+PE/3P4W+PE
Max. output current 90.9A 114.5A 136.4A 181.8A
THDv <3% (Linear load)
Load unbalance 100% three-phase unbalanced
Overload capacity ≤110%: Continues; 110%~120%: <10min; >120%: 200ms
On/off grid transfer time ≤10ms
Efficiency        
Max. efficiency 98.2%
Protection Devices        
PV reverse polarity protection Yes
Battery reverse protection Yes
AC/DC surge protection Type II
Insulation resistance monitoring Yes
Ground fault monitoring Yes
Grid monitoring Yes
Residual-current monitoring unit Yes
AC short-circuit protection Yes
Strings monitoring Yes
Anti-islanding protection Yes
PID protection Yes
AFCI function Opt
General        
Dimensions (W/H/D) 820/1350/510mm
Weight 153kg 153kg 160kg 160kg
Operating temperature range –30 °C~60 °C (> 50°C, derating)
Relative humidity 0~100%
Altitude 4000m
Topology Transformerless
Cooling Smart air cooling
IP degree IP66
Display OLED+LED/WiFi+APP
Interfaces: RS485/CAN/USB Yes
Interfaces: WIFI/LAN Opt
Warranty (5/10 years) Yes/Opt
EN 62920-2017, IEC/EN 62477-1, IEC/EN 62109-1, IEC/EN 62109-2, IEC 62116, IEC 61727, G99:2020, EN 50549-1, VDE 4105, NRS 097-2-1